Posted by WOJ on Saturday, August 04, 2001 at 1:53PM :
In Reply to: Re: Your Seeing spots posted by Harry on Friday, August 03, 2001 at 7:32AM :
FULL FLOW is impossible due to the locat1on of the oil pump. FULL FLOW oil fitration is accomplished when the oil is first passed through a filter element after it leaves the oil pump. I would like to see this for my self as I beleive it is still a BY PASS filter with a spin on cartridge as the oil leaves the pump and then goes to a common oil galley which feed the entire engine and there is NO WAY to divert it to a filter in front of the stater motor without some major casting changes to the engine.....