Re: Sterling - 1960 WM300 wiring diagram


[Follow Ups] [Post Followup] [Dodge Power Wagon Forum]


Posted by John B [74.93.60.1] on Sunday, March 17, 2013 at 22:26:22 :

In Reply to: Re: Sterling - 1960 WM300 wiring diagram posted by Sterling From TX [99.98.76.231] on Sunday, March 17, 2013 at 22:06:18 :

I would suggest that if the starter motor conductors have somehow been wired directly through the key switch rather than the heavy terminals of the solenoid you now have frozen contacts in the key switch.
The momentary contacts of the key switch and the light gauge wiring are for the solenoid coil control wiring only.
The high amperage of the starter motor would freeze the contacts, burn and melt down that small wiring in only a few seconds.
You could test or ring out that key switch, but I think it is due for replacement.





Follow Ups: